Configuring a Virtual Chassis (VC) in Junos can look daunting at first, but taken step by step it is straightforward. This is how I configure a two-member VC on Juniper QFX5100-48S-6Q switches.
Find the serial numbers
A preprovisioned VC is defined by the serial number of each member. Mine start with VF:
greg@SWITCH> show chassis hardware | match FPC
FPC 0 REV 20 650-064383 VF1234567890 QFX5100-48S-6Q
CPU BUILTIN BUILTIN FPC CPU
FPC 1 REV 08 650-064383 VF1234567891 QFX5100-48S-6Q
CPU BUILTIN BUILTIN FPC CPU
Configure the VC
set virtual-chassis preprovisioned
set virtual-chassis no-split-detection
set virtual-chassis member 0 role routing-engine
set virtual-chassis member 0 serial-number VF1234567890
set virtual-chassis member 1 role routing-engine
set virtual-chassis member 1 serial-number VF1234567891
Use no-split-detection only in a VC with exactly two members.
Form the VC
Convert the ports that connect the two switches into VC ports:
request virtual-chassis vc-port set pic-slot 0 port 48
request virtual-chassis vc-port set pic-slot 0 port 49
The PIC slot and port numbers depend on your cabling; show chassis hardware
shows them. Then watch the VC form with show virtual-chassis. FPC 0 and FPC 1
(Flexible PIC Concentrators) are the two switches, PIC 0 (Physical Interface Card)
is the physical card, and the port is the port number.
Check that it is healthy
{master:0}
greg@SWITCH> show virtual-chassis
Preprovisioned Virtual Chassis
Virtual Chassis ID: 221a.4b12.128b
Virtual Chassis Mode: Enabled
Mstr Mixed Route Neighbor List
Member ID Status Serial No Model prio Role Mode Mode ID Interface
0 (FPC 0) Prsnt VF1234567890 qfx5100-48s-6q 129 Master* N VC 1 vcp-255/0/48
1 vcp-255/0/49
1 (FPC 1) Prsnt VF1234567891 qfx5100-48s-6q 129 Backup N VC 0 vcp-255/0/48
0 vcp-255/0/49
Both members are present (Prsnt) with their serial numbers. One holds the master
role (Master*) and the other is the backup.
Management addresses and commit synchronisation
Once the VC is up, I give each member its own management address on em0 and add
a shared address that always follows the master. You are not supposed to log in to
a member directly, so the shared address is the one to use. I also enable commit
synchronisation to keep both members in sync.
set system commit synchronize
set groups member0 when member member0
set groups member0 system host-name SW1
set groups member0 interfaces em0 unit 0 family inet address 192.168.1.1/24
set groups member0 interfaces em0 unit 0 family inet address 192.168.1.3/24 master-only
set groups member1 when member member1
set groups member1 system host-name SW2
set groups member1 interfaces em0 unit 0 family inet address 192.168.1.2/24
set groups member1 interfaces em0 unit 0 family inet address 192.168.1.3/24 master-only
set apply-groups member0
set apply-groups member1
192.168.1.1 is member 0, 192.168.1.2 is member 1, and 192.168.1.3 is always
the current master. Always connect through that address, unless you know what you
are doing.